SPN 4335 FMI 13: Meaning and Fix
The ECM detects the air assist absolute pressure signal from the SCR dosing system is outside the calibrated range, typically after a software update or component replacement. Technicians often encounter this fault when a new dosing unit is installed without proper calibration, or after a forced DPF regeneration that introduces pressure spikes. The ECM compares the sensor reading against a stored reference at key-on, and deviation triggers FMI 13.
Common Symptoms
- MIL Illuminated: Amber warning lamp activates; fault logged in ECM non-volatile memory.
- Dosing Disabled: SCR reagent injection stops; NOx conversion efficiency drops sharply.
- Torque Derate: Engine power reduced by up to 25% to protect aftertreatment components.
- Poor Atomization: Air assist pressure incorrect causes large reagent droplets and deposits.
Probable Causes
- Sensor Drift: Diaphragm aging or contamination shifts the zero-point calibration offset.
- ECM Calibration Mismatch: Software version does not match sensor characteristics after replacement.
- Restricted Air Line: Partial blockage in air assist line alters pressure reading at sensor.
- Damaged Wiring Harness: Chafed 5V reference or signal wire introduces intermittent offset.
Advanced Technical Analysis
The ECM monitors the air assist pressure sensor via a 0.5–4.5V ratiometric signal. At key-on, it compares the sensor reading to an atmospheric reference stored during manufacturing. If the deviation exceeds ±3 kPa for 2 consecutive ignition cycles, FMI 13 sets. The fault remains active until a successful calibration routine completes, which requires stable sensor output below 5 kPa.
Electrical analysis shows the sensor supply pin (5V ±0.25V) must remain within 4.75–5.25V. A drop below 4.5V on the reference line due to corroded pins or high resistance can shift the sensor output by up to 10 kPa. The ECM debounces the signal for 500 ms before declaring a fault, filtering out transient spikes from air compressor cycling.
Upon activation, the ECM transitions to a safety fallback: it freezes the last known valid pressure value and continues dosing with a fixed air assist duty cycle. Torque is derated linearly from 100% to 75% over 30 minutes if the fault persists. This strategy prevents catalyst damage from poor atomization while allowing the vehicle to reach a service bay.
Long-term prevention requires verifying sensor calibration after any dosing unit replacement. Technicians should use a J1939 diagnostic tool to perform the ‘Calibrate Air Assist Pressure’ procedure (service command 0x03). In workshops, this fault recurs when aftermarket air filters are installed without checking pressure drop—always use OEM-specified filters to maintain calibration integrity.
Step-by-Step Troubleshooting Guide
- Verify Sensor Voltage: Measure signal pin voltage at key-on; should be 0.5V ±0.05V (atmospheric).
- Check Air Line Blockage: Disconnect air line at dosing unit; verify free flow with 600 kPa shop air.
- Run ECM Calibration: Use diagnostic tool to execute ‘Air Assist Pressure Calibrate’ routine.
- Inspect Connector Pins: Look for corrosion or bent pins on sensor and ECM J2 connector.