SPN 4335 FMI 9: Meaning, Symptoms and Troubleshooting

Advertisement

Diagnostic Code

SPN 4335 FMI 9: Meaning and Fix

SPN 4335 FMI 9 indicates the ECM has detected an abnormal update rate from the SCR dosing air assist absolute pressure sensor on aftertreatment system 1. This code commonly appears after a forced DPF regeneration when the air assist line is not reconnected, causing the sensor to send erratic or missing data. The ECM monitors the message frequency on the J1939 bus; if the expected periodic signal deviates by more than 20% from the nominal 100 ms interval, the fault is logged. The sensor measures pressure in kPa to ensure proper atomization of diesel exhaust fluid.

Common Symptoms

  • Engine derate: ECM reduces torque by up to 25% to protect the SCR system from poor dosing.
  • MIL illumination: Malfunction indicator lamp and SCR system warning lamp activate on the dashboard.
  • Poor atomization: DEF droplets become too large, leading to crystallization and deposit formation on the mixer.
  • Intermittent data loss: Live data shows pressure values freezing or jumping erratically between 0 and 800 kPa.

Probable Causes

  • Sensor wiring fault: Open or short circuit in the 5V reference, signal, or ground wires to the pressure sensor.
  • Faulty sensor element: Internal MEMS diaphragm failure due to vibration or moisture ingress causing signal dropout.
  • ECM software glitch: Corrupted calibration file or low battery voltage during startup disrupts message timing.
  • Air assist line blockage: Clogged or kinked air line causes pressure spikes that reset the sensor’s internal timer.

Advanced Technical Analysis

The ECM microcontroller uses a dedicated timer capture module to measure the interval between successive J1939 messages from the air assist pressure sensor. Per SAE J1939-71, the expected transmission rate is 10 Hz ±10%. If the timer capture unit detects a gap exceeding 120 ms or a burst of messages below 8 Hz, the FMI 9 is set. The diagnostic counter increments only after three consecutive failed update cycles to avoid false positives from transient noise.

Electrical analysis of the sensor circuit reveals that the sensor’s internal oscillator relies on a stable 5V supply. According to Bosch application notes, a voltage drop below 4.75V causes the sensor to reset its internal state machine, resulting in missed message frames. Using an oscilloscope on the CAN_H and CAN_L lines, technicians often observe a missing dominant bit during the arbitration phase, confirming the sensor is not transmitting its data frame at the correct time.

When FMI 9 is active, the ECM enters a fallback strategy that assumes a default air assist pressure of 350 kPa. This value is derived from Deutz engine calibration tables for medium load operation. The reagent dosing rate is reduced by 40%, and the engine torque is derated to 75% of demand. If the fault persists for over one hour of engine runtime, the ECM commands an active regeneration inhibit to prevent DEF crystallization on the SCR catalyst.

Long-term diagnostics should include a CAN bus termination check at the sensor connector. Technicians frequently encounter this fault after replacing the ECM without performing a J1939 network scan. Using a diagnostic tool like the MAN Cats II, one can verify the sensor’s source address (SA) is correctly assigned. Preventive measures include applying dielectric grease to the sensor connector and ensuring the air assist line is free of oil carryover from the compressor.

Step-by-Step Troubleshooting Guide

  1. Check CAN bus: Measure termination resistance at the sensor connector; should be 60 ohms between CAN_H and CAN_L.
  2. Inspect wiring: Verify continuity of 5V reference, signal, and ground wires; look for chafing near the DEF tank.
  3. Monitor live data: Use a J1939 tool to observe message rate; expected interval is 100 ms ±10 ms.
  4. Replace sensor: If wiring and bus are intact, replace the air assist pressure sensor and clear the fault code.