SPN 5743 FMI 2: Meaning and Fix
This fault indicates the Aftertreatment 1 SCR Temperature Sensor Module is transmitting erratic, intermittent, or incorrect data over the J1939 network to the engine ECU. The module multiplexes inputs from bank 1 SCR temperature sensors. Technicians frequently encounter this code after a forced DPF regeneration, when thermal stress causes connector pin fretting or internal module drift. It can also appear after replacing the ECM without reprogramming the module correctly.
Common Symptoms
- Erratic DEF Dosing: SCR system may under- or over-dose DEF due to incorrect temperature readings.
- Torque Derate Active: ECM activates a 25-40% torque reduction to protect aftertreatment hardware.
- MIL and Amber Lamp: Malfunction Indicator Lamp and Amber Warning Lamp illuminate on the dashboard.
- Failed OBD Readiness: Emission monitoring tests cannot complete, causing failed periodic inspections.
Probable Causes
- Module Internal Fault: Corrupted firmware or thermal damage to the module’s microcontroller.
- Damaged J1939 Harness: Chafed or pinched CAN bus wires causing signal reflection or data corruption.
- Connector Corrosion: Moisture ingress at the module connector creates intermittent resistance changes.
- ECM/Module Mismatch: Software incompatibility after ECM replacement without proper parameter download.
Advanced Technical Analysis
The ECM monitors the module’s transmitted temperature data using a rate-of-change algorithm. If the reported temperature jumps more than 15°C per second while engine conditions are stable, the ECM sets FMI 2. This debouncing timer (typically 3 seconds) prevents false triggers from transient noise, but persistent erratic values lock the fault active.
Electrical analysis of the CAN bus reveals that high-frequency noise above 500 mV peak-to-peak on the CAN_H or CAN_L lines can corrupt the module’s message arbitration. Using an oscilloscope, technicians often find a slow common-mode voltage drift caused by a failing termination resistor (120 ohms) inside the module, shifting the recessive bit voltage below 2.5 V.
When the fault is active, the ECM enters a safety fallback: it substitutes a default temperature of 250°C for SCR control, which forces the system into a conservative dosing map. This typically triggers a torque derate of 30% after 20 minutes of continuous operation. The derate is cleared only after three consecutive ignition cycles without the fault reappearing.
Long-term prevention requires inspecting the module’s mounting bracket for vibration fatigue, a known issue on Deutz TCD 2.9 engines. In one documented workshop case, replacing the module’s 4-pin connector with a Deutsch DT series (gold-plated contacts) eliminated recurrent SPN 5743 FMI 2 faults after DPF regeneration events. Always perform a J1939 CAN bus integrity test after repairs.
Step-by-Step Troubleshooting Guide
- Visual Inspection: Check module connector for bent pins, corrosion, or loose retention. Repair as needed.
- CAN Bus Test: Measure termination resistance between CAN_H and CAN_L: must be 60 ohms ± 5.
- Module Supply Check: Verify battery voltage at module pins; should be 12.0-14.5 V with ignition on.
- Firmware Reflash: Update module firmware using OEM software; recalibrate after ECM replacement.