SPN 513 FMI 2: Meaning and Fix
SPN 513 FMI 2 indicates the Engine Control Module (ECM) has detected erratic, intermittent, or incorrect actual engine percent torque data on the J1939 bus. This fault commonly appears after a forced DPF regeneration when thermal stress temporarily distorts sensor inputs, or when a technician accidentally damages the wiring harness during injector replacement. The ECM compares torque calculation from fuel rate, boost pressure, and engine speed; any discrepancy triggers this code.
Common Symptoms
- Torque Derate: ECM reduces engine power to protect components, causing noticeable loss of acceleration under load.
- Erratic Tachometer: Dashboard tachometer may fluctuate or display incorrect RPM due to corrupted torque data on the CAN bus.
- Harsh Shifting: Transmission receives erratic torque values, leading to delayed or harsh gear engagements.
- Check Engine Lamp: Amber warning lamp illuminates steadily; fault code stored in ECM non-volatile memory.
Probable Causes
- CAN Bus Corruption: Shorted or open J1939 twisted-pair wires cause intermittent torque signal transmission errors.
- ECM Software Glitch: Firmware bug in torque calculation algorithm, often triggered after ECM reflash or battery disconnect.
- Sensor Signal Noise: Electromagnetic interference from alternator or high-voltage cables distorts torque sensor readings.
- Ground Offset Fault: ECM ground circuit resistance exceeding 0.5 ohms causes erratic analog-to-digital conversion of torque data.
Advanced Technical Analysis
The ECM monitors the actual engine percent torque via internal calculation from fuel injection duration and engine speed. A debouncing timer of 1.2 seconds is used; if the torque value fluctuates more than ±15% within that window, the code sets. This logic prevents false positives from transient load changes during gear shifts.
Electrical analysis reveals that a voltage drop of >0.3V on the ECM reference supply (5V) can produce erratic torque data. Technicians should measure the CAN_H to CAN_L differential voltage; it must be between 1.5V and 3.0V with the ignition on. A reading below 1.2V indicates a bus short to ground.
When this fault is active, the ECM enters a torque derate strategy, limiting engine output to 50% of demand. The J1939 message PGN 65251 (EEC1) is substituted with a default value of 0% torque until the fault clears. This protects the drivetrain from uncontrolled torque spikes.
Long-term prevention requires verifying ECM ground integrity using a 4-wire Kelvin measurement. A common workshop example: after replacing the ECM on a MAN TGS, technicians forgot to torque the ground bolt to 12 Nm, leading to intermittent SPN 513 FMI 2. Re-torquing resolved the issue permanently.
Step-by-Step Troubleshooting Guide
- Inspect CAN Bus: Measure resistance between CAN_H and CAN_L at the diagnostic port; 60 ohms indicates proper termination.
- Check ECM Ground: Verify voltage drop between ECM ground pin and battery negative is below 0.1V with engine running.
- Review Freeze Frame: Capture engine speed, load, and battery voltage at time of fault to identify operating conditions.
- Update ECM Firmware: Flash latest manufacturer calibration to correct known torque calculation software anomalies.